CAUSATION REPORT

Collate all relevant information, including original design drawings, establishing chronology; perform a site inspection and necessary non-destructive testing including cover metre surveys, moisture metre testing, thermal imaging, flood testing to confirm points of water entry and level surveys.

 

This fact-gathering stage is integral in not only effectively establishing the cause of any damage, but also recommending the most suitable remedial option.